Table of ContentsLibraryView in Frames

Troubleshooting RLM firmware update problems with the RLM CLI

You can troubleshoot a firmware update using the RLM CLI.

Steps

  1. Verify the RLM is online by entering the following command at the storage system prompt: rlm status
  2. From a browser, access the RLM firmware file on your Web server.

    Note: Verify you are using the correct filename (filename.tar.gz) of the RLM firmware.

  3. Update the firmware by entering the following command at the RLM prompt: rlm update http://path_hostname/RLM.FW.tar.gz

    If this command fails, replace the path_hostname with the correct IP address. For detailed information on how to download and update the RLM firmware, see the Data ONTAP Upgrade Guide.

  4. Reboot the RLM by entering the following command at the storage system prompt: rlm reboot