Table of ContentsLibraryView in Frames

Viewing plex and disk pools

Viewing the disks in a plex or the spare disks in a disk pool, is useful when you are adding disks to a plex or for identifying the disk pools used by the plexes.

Step

  1. Enter one of the following commands.

    sysconfig -r

    or

    aggr status -r

    or

    vol status -r

    Example

    In this example, the aggr status -r command is used to view the disks in plexes and spare disks in disk pools.

    system1> aggr status -r
    
    Aggregate vol0 (online, raid4) (block checksums)
    Plex /vol0/plex0 (online, normal, active, pool1)
    RAID group /vol0/plex0/rg0 (normal)
    
    RAID Disk Device  HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Ph)
    --------- ------  ------------- ---- ---- ---- ----- --------------    ---
    parity    9a.16   9a    1   0   FC:A   1  FCAL 10000 34000/69632000    34
    data      9a.17   9a    1   1   FC:A   1  FCAL 10000 600/1228800       76
    data      9a.20   9a    1   4   FC:A   1  FCAL 10000 34000/69632000    34
    
    Aggregate GreG (online, raid4) (block checksums)
    Plex /GreG/plex0 (online, normal, active, pool1)
    RAID group /GreG/plex0/rg0 (normal)
    
    RAID Disk Device  HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Ph)
    --------- ------  ------------- ---- ---- ---- ----- --------------    ---
    parity    9a.18   9a    1   2   FC:A   1  FCAL 10000 34000/69632000    34
    data      9a.19   9a    1   3   FC:A   1  FCAL 10000 34000/69632000    34
    
    
    Pool1 spare disks
    
    RAID Disk       Device  HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Ph)
    ---------       ------  ------------- ---- ---- ---- ----- --------------    ---
    Spare disks for block or zoned checksum traditional volumes or aggregates
    spare           9a.24   9a    1   8   FC:A   1  FCAL 10000 34000/69632000    34
    spare           9a.29   9a    1   13  FC:A   1  FCAL 10000 34000/69632000    34
    
    Pool0 spare disks (empty)
    
    Partner disks
    
    RAID Disk       Device  HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Ph)
    ---------       ------  ------------- ---- ---- ---- ----- --------------    ---
    partner         9b.25   9b    1   9   FC:B   1  FCAL 10000 0/0               34
    partner         9b.16   9b    1   0   FC:B   1  FCAL 10000 0/0               34
    partner         9b.17   9b    1   1   FC:B   1  FCAL 10000 0/0               34
    partner         9b.21   9b    1   5   FC:B   1  FCAL 10000 0/0               34
    partner         9b.18   9b    1   2   FC:B   1  FCAL 10000 0/0               34
    partner         9b.22   9b    1   6   FC:B   1  FCAL 10000 0/0               34
    
    tpubs-cf1>

    Example

    In this example, the vol status -r command is used to view the disks in plexes and spare disks in disk pool.

    system1> vol status -r
    
    Volume vol0 (online, raid4) (block checksums)
      Plex /vol0/plex0 (online, normal, active, pool1)
        RAID group /vol0/plex0/rg0 (normal)
    
          RAID Disk Device  HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Ph)
          --------- ------  ------------- ---- ---- ---- ----- --------------    ---
          parity    9a.16   9a    1   0   FC:A   1  FCAL 10000 34000/69632000    34
          data      9a.17   9a    1   1   FC:A   1  FCAL 10000 600/1228800       76
          data      9a.20   9a    1   4   FC:A   1  FCAL 10000 34000/69632000    34
    
    Aggregate aggrz (online, raid4) (block checksums)
      Plex /aggrz/plex0 (online, normal, active, pool1)
        RAID group /aggrz/plex0/rg0 (normal)
    
          RAID Disk Device  HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Ph)
          --------- ------  ------------- ---- ---- ---- ----- --------------    ---
          parity    9a.25   9a    1   9   FC:A   1  FCAL 10000 34000/69632000    34
          data      9a.26   9a    1   10  FC:A   1  FCAL 10000 34000/69632000    34
          data      9a.27   9a    1   11  FC:A   1  FCAL 10000 34000/69632000    34
          data      9a.28   9a    1   12  FC:A   1  FCAL 10000 34000/69632000    34
    
    Pool1 spare disks
    RAID Disk       Device  HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Ph)
    ---------       ------  ------------- ---- ---- ---- ----- --------------    ---
    Spare disks for block or zoned checksum traditional volumes or aggregates
    spare           9a.24   9a    1   8   FC:A   1  FCAL 10000 34000/69632000    34
    spare           9a.29   9a    1   13  FC:A   1  FCAL 10000 34000/69632000    34
    
    Pool0 spare disks (empty)
    
    Partner disks
    RAID Disk       Device  HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Ph)
    ---------       ------  ------------- ---- ---- ---- ----- --------------    ---
    partner         9b.25   9b    1   9   FC:B   1  FCAL 10000 0/0               34
    partner         9b.16   9b    1   0   FC:B   1  FCAL 10000 0/0               34
    partner         9b.17   9b    1   1   FC:B   1  FCAL 10000 0/0               34
    partner         9b.21   9b    1   5   FC:B   1  FCAL 10000 0/0               34
    partner         9b.18   9b    1   2   FC:B   1  FCAL 10000 0/0               34
    partner         9b.22   9b    1   6   FC:B   1  FCAL 10000 0/0               34
    partner         9b.23   9b    1   7   FC:B   1  FCAL 10000 0/0               34