SystemA is unavailable, and SystemB is configured as the new DSU.
| On media server... | The following is the content of the bp.conf entry (on UNIX)/registry key (on Windows)... |
|---|---|
| mediaserver1 | NEARSTORE_FAILOVER_SERVER = SystemA:/vol/volume1 SystemB:/vol/volume1 |
| mediaserver2 | NEARSTORE_FAILOVER_SERVER=SystemA:/vol/volume2 SystemB:/vol/volume2 |
The key should be named NEARSTORE_FAILOVER_SERVER and be of type multi-string value. The value should be:SystemA:/vol/volume1 SystemB:/vol/volume1
For exact location of the registry key for Windows, see the NetBackup Administrators Guide.
The key should be named NEARSTORE_FAILOVER_SERVER and be of type multi-string value.
The value should be: SystemA:/vol/volume2 SystemB:/vol/volume2
The NearStore host name must match the listing in the Storage Device > NDMP Hosts section in NetBackup. For example, if you add SystemA as an NDMP Host to the NetBackup Storage Device by the name SystemA and add SystemB by the name SystemB.domain.com, the entry will read: SystemA:/vol/volume2 SystemB.domain.com:/vol/volume2
If no discrepancy exists between the images in the catalog and images on the NearStore volume, no images are listed in the output. The output will contain only debug logging:
STS: STH_ESDEBUG: comparedbandstu: libsts openp() 06/09/12 10:48:37: opening module /usr/openv/lib/libstspibasicdiskMT.so STS: STH_ESDEBUG: comparedbandstu: libsts openp() 06/09/12 10:48:38: opening module /usr/openv/lib/libstspinearstoreMT.so Nearstore disk subtypeIf a mismatch exists—for example, if one image did not get replicated to SystemB before SystemA went down—the output contains additional information:
STS: STH_ESDEBUG: comparedbandstu: libsts openp() 06/09/12 10:39:37: opening module /usr/openv/lib/libstspibasicdiskMT.so Nearstore disk subtype ONLY IN CATALOG imagename:mediaserver1_1157990060 policy:powerpoint_backup copy_num:1 frag_num:0 is_header:TRUE resume_num:0 ONLY IN CATALOG imagename: mediaserver1_1157990060 policy: powerpoint_backup copy_num:1 frag_num:1 is_header:FALSE resume_num:0Use the NetBackup GUI or run the bpexpdate command to remove the entries for this image from the NetBackup catalog.
The following is the bpexpdate command to remove the entry from the catalog: /usr/openv/netbackup/bin/admincmd/bpexpdate -backupid mediaserver1_1157990060 -d 0
The output will appear similiar to the following sample output:
SystemB> snapmirror status -l volume1 SnapMirror is on. Source: SystemA:volume1 Destination: SystemB:volume1 Status: Idle Progress: - State: Broken-off Lag: 00:05:28 Mirror Timestamp: Fri Sep 29 10:39:28 PDT 2006 Base Snapshot: SystemB(0101178726)_volume1.2 Current Transfer Type: - Current Transfer Error: - Contents: Replica Last Transfer Type: Resync Last Transfer Size: 72 KB Last Transfer Duration: 00:00:03 Last Transfer From: SystemA:volume1
Copyright © 1994-2008, NetApp, Inc. All rights
reserved.
Part No. 210-04225_A0
Updated for Data ONTAP 7.3.1 on 12 December 2008